Performance Optimization of Synthetic Coagulants in Laundry Wastewater Purification
DOI:
https://doi.org/10.46660/int.j.econ.environ.geol..v17i3.846Abstract
Domestic laundry wastewater is becoming a major concern due to the advent of automatic washing machines, which generate large volumes of greywater. Wastewater treatment is a big challenge due to increase in activities related to the generation of wastewater. Due to increase in the population growth rate, water scarcity is becoming a major problem. Wastewater should be treated before discharging into water bodies because it can lead to harmful effects on aquatic life and the environment. The main objectives of this study are to evaluate the performance of conventional synthetic coagulants for laundry wastewater treatment. In this study, four synthetic coagulants were used for the coagulation-flocculation process, which include alum, polyaluminium chloride, calcium chloride, and ammonium chloride. The sample was collected from an automatic washing machine. A jar test experiment was conducted, and four different dosages (1.5, 2.5, 3.5 and 4.5g/100ml) of each coagulant were taken. Physicochemical parameters: pH, electrical conductivity (EC), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total dissolved solids (TDS), and turbidity were measured before and after treatment. Results show that polyaluminium chloride shows the highest turbidity removal efficiency of 97% at a dose of 4,5g/100ml and pH level of 7, while alum shows removal efficiency (96%) at the dose of 4.5g/100ml, a pH level sustainable to 5.7. Calcium chloride shows 56%, and ammonium chloride shows only 48% turbidity removal. PAC is also best at removing suspended particles (from 64mg/l to 6mg/l) and COD from 178mg/l to 149mg/l, marginally meeting Pakistan Environmental Quality Standards. Alum shows a reduction of TSS from 67mg/l, 8mg/l, but generates acidic effluents. Calcium and ammonium chloride show limited removal of pollutants from wastewater; both of these coagulants have weak coagulation properties. TDS values of all synthetic coagulants increased with increasing dosage due to chemical dissociation of these salts into water. The results show that among all of the synthetic coagulants, PAC is the best coagulant for the treatment of laundry wastewater. Ammonium and calcium chloride are not good options for the laundry wastewater treatment.
Keywords: Synthetic coagulants, laundry wastewater, physicochemical parameters, turbidity, coagulation-flocculation.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Hafiza Swaira Shahid, Bushra Zia Khan, Rahib Hussain, Arafat Hussain

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Publisher: Society of Economic Geologists and Mineral Technologists (SEGMITE)
Copyright: © SEGMITE